Series 780S Instruction Manual Table of Contents
IM-78S-B 0-1
Sierra 780S Series Flat-Trak
Mass Flow Meter
Instruction Manual
Part Number IM-78S
07/99 Revision B
5 Harris Court, Building L Monterey, CA 93940
(831) 373-0200 (800) 866-0200 Fax (831) 373-4402
http://www.sierrainstruments.com
Sierra Instruments b.v. Bolstoen 30A 1046 AV Amsterdam The Netherlands
+31(0)20-6145810 Fax +31(0)20-6145815
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Instruction Manual

Series 780S Instruction Manual Table of ContentsIM-78S-B 0-1Sierra 780S Series Flat-Trak™Mass Flow MeterInstruction ManualPart Number IM-78S07/99 Revi

Page 2 - Customer Notice

Chapter 1 Introduction Series 780S Instruction Manual1-4 IM-78S-BSmart Electronics FeaturesInstrument ValidationTwo simple tests offer full “field-val

Page 3 - Table of Contents

Series 780S Instruction Manual Chapter 1 IntroductionIM-78S-B 1-5TotalizerWith the optional LCD display, actual mass flow appears on line 1and the tot

Page 4 - List of Tables

Chapter 1 Introduction Series 780S Instruction Manual1-6 IM-78S-B

Page 5 - Warnings and Cautions

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-1Chapter 2 InstallationInstallation OverviewThe Series 780S Flat-Trak™ is available w

Page 6 - 0-6 IM-78S-B

Chapter 2 Installation Series 780S Instruction Manual2-2 IM-78S-BUnobstructed Flow RequirementsSelect an installation site that will minimize possible

Page 7 - Chapter 1 Introduction

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-3To install the flow meter:1. Turn off the flow of process gas. Verify that the line

Page 8 - Technical Assistance

Chapter 2 Installation Series 780S Instruction Manual2-4 IM-78S-BWiring ConnectionsFor NEMA 4X enclosures, use TB2 for power and signal connec-tions,

Page 9 - IM-78S-B 1-3

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-5Input Power WiringAC Power WiringThe AC power wire size must be 26 to 16 AWG with the

Page 10 - Smart Electronics Features

Chapter 2 Installation Series 780S Instruction Manual2-6 IM-78S-BDC Power WiringThe DC power wire size must be 26 to 16 AWG with the wirestripped 1/4

Page 11 - Software

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-7Output Signal WiringOutput signal cable should be completely screened with a 100%shie

Page 12 - 1-6 IM-78S-B

Table of Contents Series 780S Instruction Manual0-2 IM-78S-BCustomer Notice Sierra Instruments, Inc. is not liable for any damage or personal injury,

Page 13 - Chapter 2 Installation

Chapter 2 Installation Series 780S Instruction Manual2-8 IM-78S-B4-20 mA Output WiringThe 4-20 mA current loop output can be self-powered (non-isolate

Page 14 - Installing the Flow Meter

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-9R load4-20 out (+)4-20 out (–)12 VDCto36 VDCCurrent– +121516NEMA 4X Enclosu

Page 15 - IM-78S-B 2-3

Chapter 2 Installation Series 780S Instruction Manual2-10 IM-78S-BAlarm Output WiringTwo alarm outputs (Low Alarm and High Alarm) are included on thef

Page 16 - Wiring Connections

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-111234567891020191817161514131211Hazardous-Area EnclosuresLoad LoadLO ALARM (–)AC or

Page 17 - Input Power Wiring

Chapter 2 Installation Series 780S Instruction Manual2-12 IM-78S-BVelocitysensorREDGREENORANGEWHITEBLACKTemperaturesensorRemote enclosureSensorprobeNE

Page 18 - 2-6 IM-78S-B

Series 780S Instruction Manual Chapter 2 InstallationIM-78S-B 2-13Figure 2-22. Sensor Junction Box to Remote Enclosure ConnectionsRange Selection Wiri

Page 19 - Output Signal Wiring

Chapter 2 Installation Series 780S Instruction Manual2-14 IM-78S-B

Page 20 - 2-8 IM-78S-B

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-1Chapter 3 OperationThis chapter covers flow meter operation, programming and instru-men

Page 21 - Hazardous-Area Enclosures

Chapter 3 Operation Series 780S Instruction Manual3-2 IM-78S-BUsing the Smart Electronics Basic FeaturesThis section covers the basic features of the

Page 22 - Alarm Output Wiring

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-3LCD Display Programming MenuVersionSerial No.SierraFlow MeterCurrent flow rate Totalized

Page 23 - Remote Sensor Probe Wiring

Series 780S Instruction Manual Table of ContentsIM-78S-B 0-3Table of ContentsChapter 1 IntroductionSeries 780S Flat-Trak Mass Flow Meters ...

Page 24 - 2-12 IM-78S-B

Chapter 3 Operation Series 780S Instruction Manual3-4 IM-78S-BSingle-Digit LED Programming Menu FUNCTION AssignmentsVersionVoltage SpanVoltage ZeroHig

Page 25 - Range Selection Wiring

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-5Entering Alarm ParametersUse the High Alarm and Low Alarm function to set or adjust alar

Page 26 - 2-14 IM-78S-B

Chapter 3 Operation Series 780S Instruction Manual3-6 IM-78S-BK-Factor AdjustmentEntering a K-factor adjusts the meter’s output signal without affect-

Page 27 - Chapter 3 Operation

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-7User Full Scale AdjustmentThe user full scale (UFS) feature adjusts the flow meter outpu

Page 28 - 3-2 IM-78S-B

Chapter 3 Operation Series 780S Instruction Manual3-8 IM-78S-BTime Response Delay AdjustmentChanging the Time Response Delay using the LCD Display1.

Page 29 - LCD Display Programming Menu

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-9Totalizer ResetIf your device is equipped with the optional LCD display, reset thetotali

Page 30 - 3-4 IM-78S-B

Chapter 3 Operation Series 780S Instruction Manual3-10 IM-78S-B

Page 31 - Entering Alarm Parameters

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-11Using the Smart Electronics Advanced FeaturesZero and span (Function 1 through 4) can b

Page 32 - K-Factor Adjustment

Chapter 3 Operation Series 780S Instruction Manual3-12 IM-78S-BNote: when adjusting zero the current signal will be driven to 4 mA andwhen adjusting s

Page 33 - User Full Scale Adjustment

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-13Instrument ValidationSystem electronics are verified by injecting a known input value a

Page 34 - 3-8 IM-78S-B

Table of Contents Series 780S Instruction Manual0-4 IM-78S-BChapter 4 Troubleshooting and RepairTroubleshooting the Flow Meter...

Page 35 - Totalizer Reset

Chapter 3 Operation Series 780S Instruction Manual3-14 IM-78S-BElectronics Validation Procedure1. Verify the flow meter is off line from any remote c

Page 36 - 3-10 IM-78S-B

Series 780S Instruction Manual Chapter 3 OperationIM-78S-B 3-15Calibration Certificate Values Validation Test ResultsSamplePointBridgeVoltageIndicated

Page 37 - Voltage Span Adjustment

Chapter 3 Operation Series 780S Instruction Manual3-16 IM-78S-B4. Set the multimeter to read Ohms in the 2K range. Connect themultimeter to the termi

Page 38 - Current Span Adjustment

Series 780S Instruction Manual Chapter 4 Troubleshooting & RepairIM-78S-B 4-1Chapter 4 Troubleshooting and RepairTroubleshooting the Flow MeterBe

Page 39 - Instrument Validation

Chapter 4 Troubleshooting & Repair Series 780S Instruction Manual4-2 IM-78S-BProblem Possible Cause SolutionVelocity measurement iserratic or fluc

Page 40 - 3-14 IM-78S-B

Series 780S Instruction Manual Chapter 4 Troubleshooting & RepairIM-78S-B 4-3Returning Equipment to FactoryBefore returning any mass flow meter to

Page 41 - Sensor Validation Procedure

Chapter 4 Troubleshooting & Repair Series 780S Instruction Manual4-4 IM-78S-B

Page 42 - 3-16 IM-78S-B

Series 780S Instruction Manual Appendix A SpecificationsIM-78S-B A-1Appendix A Product SpecificationsPerformance SpecificationsAccuracy ± 2% of readin

Page 43 - IM-78S-B 4-1

Appendix A Specifications Series 780S Instruction ManualA-2 IM-78S-BLeak Integrity 1 X 10–4 atm cc/sec of helium maximumPower Requirements 18 to 30 VD

Page 44 - 4-2 IM-78S-B

Series 780S Instruction Manual Table of ContentsIM-78S-B 0-5Warnings and CautionsWarning! Agency approval for hazardous location installations varies

Page 45

Table of Contents Series 780S Instruction Manual0-6 IM-78S-B

Page 46 - 4-4 IM-78S-B

Series 780S Instruction Manual Chapter 1 IntroductionIM-78S-B 1-1Chapter 1 IntroductionSeries 780S Flat-Trak™ Mass Flow MetersSierra’s Series 780S Fla

Page 47 - IM-78S-B A-1

Chapter 1 Introduction Series 780S Instruction Manual1-2 IM-78S-BNote and Safety InformationWe use note, caution and warning statements throughout thi

Page 48 - A-2 IM-78S-B

Series 780S Instruction Manual Chapter 1 IntroductionIM-78S-B 1-3The Series 780S Flow Sensing PrincipleSierra’s unique Steel-Trak™ sensor probe is res

Comments to this Manuals